Empty Space
Cummins Fire power Logo Center Image
Spacer
Home Site Map  
 
Red boxes
   
Engines

Engine Selector

USA Engines(HP)

USA Engines (kW)

International Engines (HP)

International Engines (kW)

UL Listed Drive-Shafts

Product Brochure

Product Registration

Exhaust Sizing

Important Notice about vertical turbine applications:

NFPA-20 states the following:

7.5.1.6.1 For drive systems that include a right angle gear drive, the pump manufacturer shall provide a complete mass elastic system torsional analysis to ensure there are no damaging stresses or critical speeds within 25 percent above and below the operating speed of the pump and drive.

7.5.1.6.2 The torsional analysis specified in 7.5.1.6.1 shall include the mass elastic characteristics for a wetted pump with the specific impeller trim, coupling, right-angle gear, flexible connecting shaft, and engine, plus the excitation characteristics of the engine.

 

Cummins Fire Power UL Listed Drive-Shafts
EVERY PRODUCT.
Our certified short couple drive shafts are genuine Spicer shafts built and tested to the stringent UL 448A requirements for proven reliability and longevity over the life of your diesel fire pump driver.

Check out our CFP engine model-to-drive shaft selection matrix. The matrix has both listed and non-listed shafts on it. Matrix.

Model
PN#
Min Speed RPM
Max HP / Torque
(lb-ft) @ Min Speed
Max Speed RPM
Max HP / Torque
(lb-ft) @ Max Speed
13417 1470 106 / 379 1760 120 / 359
13417 1760 120 / 359 2100 136 / 341
13417 2100 136 / 341 2350 148 / 330
13417 2359 148 / 330 2600 158 / 320
1480 13418 1470 140 / 499 1760 159 / 473
13418 1760 159 / 473 1900 167 / 462
13418 1900 167 / 462 2100 179 / 448
13418 2350 194 / 434 2600 208 / 420
1550 13419 1470 175 / 625 1760 198 / 592
13419 1760 198 / 592 1900 209 / 579
13419 1900 209 / 579 2100 225 / 562
13419 2100 225 / 562 2350 243 / 543
13419 2350 243 / 543 2600 260 / 526
13419 2600 260 / 526 2800 275 / 515
13419 2800 275 / 515 3000 288 / 505
1610 13420 1470 266 / 950 1900 344 / 950
13420 1900 344 / 950 2100 378 / 946
13420 2100 378 / 946 2350 409 / 915
13420 2350 409 / 915 2600 439 / 887
13420 2600 439 / 887 2800 463 / 868
13420 2800 463 / 868 3000 486 / 850
1710 13421 1470 336 / 1200 2300 526 / 1200
1810 13422 1470 427 / 1525 2100 610 / 1525
1880 13423 1470 604 / 2158 1760 686 / 2046
13423 1760 686 / 2046 1800 697 / 2034

3172

13430 1470 616 / 2200 1760 730 / 2177
13430 1760 730 / 2177 1800 741 / 2163

 

Notice

 

A service factor must be applied to the calculated end-use application torque. The calculated end-use application torques, as adjusted by the service factor, shall not exceed the torque rating of the connecting shaft at the applicable speed.

Service Factor (SF) = 1.5
(6 Cylinders or More -diesel engine)

Service Factor (SF) = 2.0
(5 Cylinders or Less-diesel engine)


Selection of Flexible connecting driveshaft shall be based on rating of the driver and not the pump.

Although UL listed torque ratings are shown at specific speeds, CFP drive-shafts can be applied at any intermediate speed. To determine the intermediate certified power, make a linear interpolation from the CFP UL Listed power curve. Contact Cummins Fire Power if you have questions.

 
 
Drive-Shaft Manual

Blank Space

Home
| Site Map | Privacy Policy and Terms of Use and Disclaimers
 
UL Logo C UL Logo
© 2010 Cummins Fire Power, 875 Lawrence Drive, De Pere, WI 54115 U.S.A.
2010 Cummins Inc. All rights reserved. Cummins and its logo designs are trademarks of Cummins Inc.